Start with the job (free amino acids, total amino acids, label-claim verification or a single analyte), then compare labs on method, panel, calibration, report evidence, sample preparation, re-run practice and plainly stated status. If a contract or regulator names ISO 17025, you need an accredited lab. OpenChemWorks is not yet accredited; we run research testing and put the chromatogram, calibration and QC results in every report.
Start with the question, not the lab
"Amino acid analysis" covers at least four different jobs, and labs are not interchangeable across them.
- Free amino acids: what is dissolved and unbound in a drink, hydrolysate, fermentation broth or spent media sample, as it is.
- Total amino acids: everything in a protein or powder, which requires hydrolysing the sample first (typically 6 N HCl, 110 °C, 24 hours) to break the protein into its amino acids before measurement.
- Label-claim verification: a finished supplement measured against what its panel promises, per lot.
- A single analyte: one amino acid, or a non-amino-acid ingredient such as creatine, that needs its own method.
A lab that is excellent at one can be wrong for another. A lab that quotes a panel price without asking what your sample is, or whether you need free or total, is selling a test, not an answer.
What it costs here
Prices are published and you can order online. Compare any quote on the same basis: the job, the panel, preparation, and the all-in total for your sample count. For other laboratories' published prices, see the price index.
| Test | What you get | Price per sample |
|---|---|---|
| AA-1 free amino acid profile | 19 amino acids plus ammonia, in µM and mg/L | $150 ($125 at 15+ samples a month, $99 at 30+) |
| AA-1 (Taurine) | The full AA-1 analysis with taurine added. Taurine is not in the standard 19 amino acid panel | $150 |
| AA-T total amino acid profile | 16 amino acids after acid hydrolysis, in g/100 g and mol% | $230, hydrolysis included |
| CR-1 creatine | Creatine by HPLC-UV, % w/w or mg per serving | $120 |
| PREP-1 solids and powders | Weighing, extraction and filtration | +$30 (none for powders that simply dissolve) |
| RUN-1 bioreactor run | One run, up to 24 time points, AA-1 on each | $1,990 per run |
| PILOT | 5 AA-1 samples with full report, one per company | $250, credited in full toward a first order of 20+ samples within 90 days |
Minimum order is $150. Overnight turnaround available, with expedited service on request. Standard results in 3 to 5 business days from receipt. See an example report.
Order samples See an example report
Seven things that matter
- Method, and whether they will name it. The established routes are AQC derivatization with HPLC, OPA/FMOC HPLC, ion-exchange with post-column ninhydrin (the long-standing reference approach), and LC-MS. Each has real strengths. What matters is that the lab names its method on the report, the method fits your matrix, and the lab can say what it cannot see. Ours is AQC derivatization with HPLC and dual UV (260 nm) and fluorescence detection. It measures amino acids and ammonia; creatine needs a separate test (CR-1).
- The panel, measured individually, not inferred. A real amino acid panel reports each amino acid as its own number. Be wary of any "protein" figure built from total nitrogen x 6.25: it cannot tell protein from free amino acids or other nitrogen sources, which is exactly the spiking pattern supplement buyers need to catch. Ask how many analytes are named per sample. Ours is 19 of the 20 standard amino acids plus ammonia (cysteine needs the AA-3 workup), with an extended panel (GABA, ornithine, citrulline, hydroxyproline) available.
- Calibration you can trace. Every run should be calibrated against reference standards, with a check standard in the run, and the report should say so. Press on "in-house mix" language.
- Evidence in the report, not just a number. A report you can defend shows per-analyte results in stated units, the chromatogram, the named method, the sample preparation and the QC results. A one-line certificate with a pass/fail stamp gives you nothing to show your boss, your retailer or your own QA file. Every OpenChemWorks report includes the chromatogram, calibration and QC results. Here is an example report.
- Sample preparation fit. Powders need a defined dissolve-and-dilute step, total amino acid work needs hydrolysis, and drinks, gummies and broths each change the prep. Ask how your sample type is prepared and how much sample they need. Ours: liquids 200 µL per sample (400 µL preferred), solids at least 100 mg.
- What happens when a result looks wrong. Good labs re-run unexpected results before reporting and keep the raw data. Ask before you ship, not after a number surprises you.
- Turnaround. Overnight turnaround available, with expedited service on request. Standard results in 3 to 5 business days from receipt. How many samples fit overnight depends on the sample type and prep. Tell us your sample count and type, and we will confirm timing.
Do you need an accredited lab?
We are not yet accredited. OpenChemWorks is not accredited to ISO 17025, and we do not operate under GLP or GMP. We provide research testing for research, product development and process monitoring.
That means our reports are the right fit when the decision is internal: comparing blends, checking a supplier's powder against its specification, screening a lot before a bigger spend, or following amino acids through a fermentation or cell culture run. Every report shows the chromatogram, the calibration and the QC results, so you can judge the numbers yourself.
They are not the right fit when a contract, a retailer programme, a regulator or a regulatory filing names accreditation or a specific method. In that case you need an accredited lab, and you should ask that lab for its certificate and its scope, because the scope must list your matrix and analyte. If you are unsure, send us the wording. We will tell you plainly whether our report fits, before you spend anything.
Plasma and other human samples are for research use only, not for clinical diagnosis.
Three lab shapes, honestly compared
| Large accredited contract lab | University or core facility | Small specialist lab (us) | |
|---|---|---|---|
| Best at | Regulatory, release and contract-specified work; broad scopes | Research questions, unusual matrices, method access | One panel done transparently; label-claim and screening work |
| Watch for | Long queues, minimums, a scope that may not list your matrix | Academic timelines; reports not written for QA files | Narrow scope, not accredited; check the job is inside it |
| Report | Formal, scope-backed | Data-forward, format varies | Chromatogram, calibration, QC and per-analyte numbers |
| Choose when | A contract or regulator names accreditation | The science is the hard part | The decision is internal and you want to see the evidence |
No column of that table is "best." The right lab is the one whose evidence matches the decision the result has to carry.
Red flags, from any lab
- It will not name the method, or the method changes between quote and report.
- A "protein" result with no per-amino-acid breakdown.
- No chromatogram available on request.
- Accreditation implied by a logo, with no certificate and scope to show.
- A price with no statement of what is included: panel, prep, re-runs, report.
- Certainty about your matrix before they have asked what it is.
Questions to send before you ship
- Free or total: which does my job need, and which are you quoting?
- Which analytes are reported individually? What can your method not see?
- What standards calibrate the run, and is a check standard included?
- What will the report show? Can I see an example report?
- How is my sample type prepared, and how much do you need?
- If a result looks off, do you re-run before reporting? Is that charged?
- What is your accreditation and validation status, in writing?
- How fast will I get results, and can you run overnight?
A lab that answers all eight clearly has earned the sample, whoever it is.
Where we fit
OpenChemWorks is the third column of the table: a small specialist lab running AQC with HPLC and dual UV and fluorescence detection, with the chromatogram, calibration and QC results in every report. Unexpected results are re-run before reporting. Tell us what your results are for and we will confirm the fit before you ship. Related: how much sample to send and how much amino acid testing costs.
OpenChemWorks Laboratory · Reviewed by the OpenChemWorks laboratory · Published October 30, 2026 · Updated November 19, 2026