Services · AA-1, AA-2, AA-3

Amino Acid Analysis by AQC Derivatization and HPLC

19 amino acids and ammonia per sample, an extended panel on request, and a report that includes the chromatogram and the QC behind every number.

Free amino acids, reported in µM and mg/L

The standard profile (AA-1) measures 19 amino acids and ammonia by pre-column derivatization with AQC, reversed-phase HPLC on a C18 column and UV detection at 260 nm. The extended panel (AA-2) adds five non-protein amino acids to the same run. Clarification and deproteinization of liquid samples are included.

How the chemistry works is in the methods library; how we control quality is on its own page; how to read a result is in reading an amino acid profile.

Analytes reported

Standard panel (AA-1), 19 amino acids + ammonia: alanine, arginine, asparagine, aspartate, glutamate, glutamine, glycine, histidine, isoleucine, leucine, lysine, methionine, phenylalanine, proline, serine, threonine, tryptophan, tyrosine, valine; ammonia.

Extended panel (AA-2): GABA, ornithine, citrulline, taurine, hydroxyproline.

On request: cysteine / cystine.

Prices

CodeServiceIncludes1–910–4950 +
AA-1Free amino acid profile19 amino acids + ammonia, µM and mg/LPDF report with chromatogram, calibration and QC summary$125$99$79
AA-2Extended panelGABA, ornithine, citrulline, taurine, hydroxyprolinesame run, added to AA-1+ $25+ $25+ $25
AA-3Cysteine / cystinereduction–alkylation workupon request
RUSH48-hour rushsubject to capacity+ 100 %
PREP-1Solids and powdersweighing, extraction and filtration of hydrolysate powders, feed, plant material+ $30
PREP-2New-matrix qualificationspike-recovery check the first time we see a matrix typewaived at 20 + samples$200 once

Minimum order $150. Typically 5 business days. Order estimator →

Example report First page of an OpenChemWorks amino acid analysis report

Every result comes with the data behind it.

Each report includes the results table, the chromatogram and the run's quality-control summary, so your methods section or process record has what it needs.

Internal standard in every sampleMonitors derivatization and injection for each sample
QC standard in every runA known amino acid mixture confirms the calibration holds for that run
Sensitivity and recovery checksDetector response verified; spiked amino acids where the matrix calls for it
Reagent blanksRun with the samples; results below the quantitation limit are flagged

Open the Example Report (PDF)

Have samples in mind?

Published prices, a person replies, and every report includes the chromatogram and QC behind the numbers.